Practical Validation Measurements of a Physiological Status Monitoring Sensor in Real Construction Activities

Moohialdin, A, Trigunarsyah, B and Siddiqui, M 2018, 'Practical Validation Measurements of a Physiological Status Monitoring Sensor in Real Construction Activities', in Streamlining Information Transfer between Construction and Structural Engineering, Brisbane, Dec 3-5 2018, pp. 1-6.


Document type: Conference Paper
Collection: Conference Papers

Title Practical Validation Measurements of a Physiological Status Monitoring Sensor in Real Construction Activities
Author(s) Moohialdin, A
Trigunarsyah, B
Siddiqui, M
Year 2018
Conference name the Fourth Australasia and South-East Asia Structural Engineering and Construction Conference
Conference location Brisbane
Conference dates Dec 3-5 2018
Proceedings title Streamlining Information Transfer between Construction and Structural Engineering
Publisher ISEC Press
Place of publication Fargo, USA
Start page 1
End page 6
Total pages 6
Abstract The construction industry is one of the most hazardous industry and construction worker's health and safety in hot and humid weather conditions become a topic of a great interest for researchers and practitioners. Various physiological monitoring sensors have been employed to measure the physiological impacts of such weather conditions. However, the ability of these sensors to deal with the dynamic nature of the construction industry still under controversial arguments and there is a need to justify their applicability in real working conditions. This paper aims to investigate the accuracy of an off-the-shelf physiological monitoring sensor (Zephyr BioHarnessTM 3) in a real working environment when considering the impact of hot and humid weather conditions. Fifteen different construction workers participated in three site measurements, with monitoring two physiological parameters heart rate (HR) and breathing rate (BR). A non-parametric statistical test (Mann-Whitney) was applied to identify whether there is a significant difference between the medians of live data in the remote monitoring station and saved data of the sensor internal memories. The results showed that there are significant differences between live data and saved data. These differences were highly noticed in the third site measurements, as it included working in confined areas and trenches. The accuracy of live data is highly affected by types of activities and appropriate positions of the wireless connection devices (ECHO gate and repeater).
Subjects Building Construction Management and Project Planning
Construction Engineering
Keyword(s) Zephyr BioHarnessTM 3
Health and safety related on-site data collection
Heart rate
Breathing rate
Copyright notice © 2018 ISEC Press
ISBN 9780996043779
Versions
Version Filter Type
Access Statistics: 7 Abstract Views  -  Detailed Statistics
Created: Tue, 26 Mar 2019, 09:36:00 EST by Catalyst Administrator
© 2014 RMIT Research Repository • Powered by Fez SoftwareContact us