Prediction of compressive and tensile strengths of zeolite-cemented sand using porosity and composition

MolaAbasi, H, Saberian Boroujeni, M and Li, J 2019, 'Prediction of compressive and tensile strengths of zeolite-cemented sand using porosity and composition', Construction and Building Materials, vol. 202, pp. 784-795.


Document type: Journal Article
Collection: Journal Articles

Title Prediction of compressive and tensile strengths of zeolite-cemented sand using porosity and composition
Author(s) MolaAbasi, H
Saberian Boroujeni, M
Li, J
Year 2019
Journal name Construction and Building Materials
Volume number 202
Start page 784
End page 795
Total pages 12
Publisher Elsevier
Abstract The current paper aims to examine the effects of cement and zeolite contents on the strength of zeolite-cemented sand using the unconfined compressive strength (UCS) and splitting tensile strength (q(t)). First of all, the optimum content (i.e., the corresponding water content to the maximum UCS) was obtained from the response surface (RSM) and central composite design (CCD) methods. Then, unconfined compression and splitting tensile tests considering four distinct porosity percentages (TO related to D-rsand = 35, 50, 70 and 85% (Dr = relative density), five cement contents (2, 4, 6, 8. and 10%), and six different percentages of zeolite replacement (0, 10, 30, 50, 70 and 90%) were performed. Then, the amounts of the improved UCS and qt of the specimens as a result of the porosity, zeolite and cement were measured. The results indicated that the 30% replacement of cement with zeolite (Z) was found the optimum amount of replacement. The strength improvement rate of the optimum zeolite-cemented sand (Z = 30%) compared to the mere cemented sand (Z = 0%) increased with the increase in the cement content as well as increase in the porosity of the compacted mixture. Based on the results of the zeolite-cement-sand mixtures, it has been shown that the UCS and qt improved by increasing the cement content (C). Also, the power function is well-matched to fit (UCS and qt)-C. The active composition parameter (AC) participate in the chemical reaction was introduced, as the minimum amount of either CaO or Al2O3 + SiO2. Afterward, the UCS and qt were plotted against the porosity/active composition parameter (VAC), which is regarded as a controlling and key parameter of the UCS and qv Also, the experimental results and the parameter of eta(-1.79)AC(1.43) introduce an acceptable description of the mechanical strength. Finally, the q(t)/UCS relationship is unique for the zeolite-cemented sand studied, being independent of the eta/AC. (C) 2019 Elsevier Ltd. All rights reserved.
Subject Civil Geotechnical Engineering
Keyword(s) Active composition
Cement
Compressive strength
Stabilization
Tensile strength
Zeolite
DOI - identifier 10.1016/j.conbuildmat.2019.01.065
Copyright notice © 2019 Elsevier Ltd. All rights reserved.
ISSN 0950-0618
Versions
Version Filter Type
Citation counts: TR Web of Science Citation Count  Cited 3 times in Thomson Reuters Web of Science Article | Citations
Scopus Citation Count Cited 0 times in Scopus Article
Altmetric details:
Access Statistics: 12 Abstract Views  -  Detailed Statistics
Created: Thu, 23 May 2019, 08:44:00 EST by Catalyst Administrator
© 2014 RMIT Research Repository • Powered by Fez SoftwareContact us